- Contact Person : Ms. Fan Jane
- Company Name : Kaiying Power Supply & Electrical Equip Co., Ltd.
- Tel : 0086-0595-22999998
- Fax : 0086-0595-22281999
- Address : Fujian,quanzhou,Kaiying industrical park,chengxiang town,anxi,quanzhou,fujian ,China
- Country/Region : China
- Zip : 362000
UPS storage battery
Nominal Voltage:12Vstorage battery1)12v UPS battery with Reliably sealed construction 2)Long service life, float or cyclic3)UL and CE test
storage battery
PHYSICAL SPECIFICATIONS1)Nominal Voltage:12V Nominal Capacity (10HR):17.0AH Dimensions:181*77*167(mm)±2mm Weight:5.1kgs/Standard Terminals:T10/T31.1 Sealed Construction
1.2 Absorptive Glass Mat System (AGM System)
1.3 Gas Recombination
1.4 Maintenance-Free Operation
1.5 Position-Free and Leakage-Free
1.6 Stable Quality & High Reliability
1.7 Long Service Life, Float or Cyclic
1.8KAIYING batteries are equipped with a safe, low pressure venting system1.9 Heavy-Duty Grids
1.10 Low Self Discharge
1.11 High Recovery Capability
1.12 U. L. and C.E. Component Recognition
measuring equipment and instrumenttelephone setslighting equipmentsecurity systems
Battery with different mode of charge and discharge and lifeRecycle discharge and chargeIf the device connected with power supply charge may be moved after saturation then the battery supply equal to power supply power resource.There is limit for highest voltage offered by charger when charge electricity: 2V battery charge voltage: 2.6-2.75V;6V battery charge voltage: 7.2-7.5V; 12V battery charge voltage: 14.4-15.0V. The largest current is not higher (that rated capacity 30% A. For example 6V4AH, The largest current is not higher I=0.3×4A=1.2A )Charge must be stopped when chargers show saturation. Otherwise the battery may be damaged or injured.If according to the Japanese standard-JISC industry, the battery cycling life is up to 250 times.Circulatory charge and discharge (in a circle).Mode of float charge1. Of the equipment always been connected power supply and controlled by has been charged, only when external power supply is stopped by battery, In this mode, please choose the float charge mode.
2. The highest charging voltage of float charge mode machine should be strictly controlled. The float charge voltage at 250C is: 2.26-2.30V/cell, the largest charging current should not be larger than the rating capacity’s 30%A.
3. The float charge life: the float charge life is more than one year for the battery that the capacity≤24Ah, to the capacity is more than 24Ah, it’s life is more than three years.
Discharge
The discharge time is more than 20 hours when the voltage is up to 1.8V/cell should be end discharge. The discharge time is between two and twenty hours when the voltage is up to 1.7V/cell should be end discharge; The discharge time is less than tow hours when the voltage is up to 1.6V/cell should be end discharge. Otherwise the battery may be damaged. When discharge is end should be immediately charged.
UPS storage battery